| L300P Specifications |
Appearance |

|
Power
Source |
Rated
input
voltage |
1-phase |
- |
| 3-phase (200V) |
200-240V
+/-10%, 50/60Hz |
| 3-phase (400V) |
380-480V
+/-10%, 50/60Hz |
| Applicable motor |
1.5-132kW |
| Output frequency range |
0.1-400Hz |
| Starting torque |
100%
or greater (Torque boost mode) |
Continuous operating torque
speed range |
- |
| Braking torque |
Dynamic
brake
(capacitor feedback) |
- |
| DC
brake |
Variable
operating frequency, time, and braking force |
| Overload capacity |
120%,
60sec., 150%, 0.5sec. |
| Acceleration/deceleration time |
0.01-3,600sec. |
| Multispeed operation |
Max.
16-stage (Bit command also available) |
Analog input
for frequency control |
0-10VDC,
4-20mA, -10 to +10VDC. |
| Protective funcitons |
Over-current
protection, overload protection, braking resistor overload protection, over-voltage
protection, EEPROM error, under-voltage error, CT(Current transformer) error, CPU error,
external trip, USP error, ground fault, input over-voltage protection, instantaneous power
failure, option 1 connection error, option 2 connection error, inverter thermal trip,
phase failure detection, IGBT error, thermistor error |
| Other functions |
V/f
free-setting (up to 7 points), frequency upper/lower limit, frequency jump, accel./decel.
curve selection, manual torque boost value and frequency adjustment, analog meter tuning,
starting frequency, carrier frequency, electronic thermal protection level, external
frequency output zero/span reference, external frequency input bias start/end, analog
input selecction, retry after trip, reduced voltage soft start, overload restriction,
automatic energy-saving |
Environmental
Conditions |
Ambient operating temperature |
-10
to 40 °C* |
| Humidity |
25 to
90%RH(No condensation) |
| Location |
When
using the inverter from 40°C to 50°C ambient, the output current of the inverter must be
derated. |
|
| *See derating data and
carrier frequency adjustment in instruction manual when ambient operating temperature is
40°C or over. |
|
| L300P Dimensions |
[Unit: mm(inch)]
(Inches for reference only) |
| L300P- |
015HFE2, 022HFE2
040HFE2, 055HFE2 |
110HFE2,
150HFE2 |
185HFE2,
220HFE2,
300HFE2 |
370HFE2 |
450HFE2,
550HFE2 |
- |
900HFE2,
1100HFE2 |
1320HFE2 |
015LFU2, 022LFU2,
037LFU2, 055LFU2 |
110LFU2,
150LFU2 |
185LFU2,
220LFU2,
300LFU2 |
370LFU2 |
450LFU2,
550LFU2 |
750LFU2 |
- |
- |
015HFU2, 022HFU2
040HFU2, 055HFU2 |
110HFU2,
150HFU2 |
185HFU2,
220HFU2,
300HFU |
370HFU2 |
450HFU2,
550HFU2 |
- |
900HFU2,
1100HFU2 |
1320HFU2 |
| Width |
150(5.91) |
210(8.27) |
250(9.84) |
310(12.20) |
390(15.35) |
480(18.90) |
390(15.35) |
480(18.90) |
| Height |
255(10.04) |
260(10.24) |
390(15.35) |
540(21.26)
(*6) |
550(21.65)
(*7) |
700(27.56)
(*8) |
700(27.56) |
740(29.13) |
| Depth |
140(5.51)(*9) |
170(6.69)
(*9) |
190(7.48)
(*9) |
195(7.68)
(*9) |
250(9.84)
(*9) |
250(9.84)
(*9) |
270(10.63)
(*9) |
270(10.63)
(*9) |
|
|
*
Note 6: Add 100mm (3.94inches) for conduit box
Note 7: Add 80mm (3.15inches) for conduit box
Note 8: Add 70mm (2.76inches) for conduit box
Note 9: Add 8.5mm (0.33inch) for potentiometer |
|
|